🔧 Built-In Diagnostic Service

Having connection issues? Use our built-in diagnostic service to test your connection before installing the integration!


✨ What It Does

The Universal Register Scanner diagnostic service:

  • ✅ Tests TCP connection to your adapter
  • ✅ Auto-detects your inverter model (VPP 2.01 inverters)
  • ✅ Scans all register ranges automatically
  • ✅ Validates responses are correct
  • ✅ Shows results as a notification
  • ✅ Exports complete register dump to CSV
  • No Terminal or SSH needed!

Note: For VPP Protocol V2.01-capable inverters, auto-detection identifies your model automatically. Legacy protocol inverters require manual model selection.


🚀 How to Use

Step 1: Install the Integration Files

You don't need to configure the integration, just have the files installed:

  1. Download the latest release
  2. Extract to /config/custom_components/growatt_modbus/
  3. Restart Home Assistant

The diagnostic service will be available immediately!

Step 2: Run the Diagnostic

  1. Go to Developer ToolsActions
  2. Search for "Growatt Modbus: Universal Register Scanner"
  3. Select your inverter from the Device dropdown (recommended), or enter connection parameters manually
  4. Click "Perform Action"

The scanner will: - Automatically detect your model (if VPP 2.01 supported) - Scan all register ranges (0-124, 125-249, 1000-1124, 3000-3249) - Show detection confidence rating (High/Medium/Low) - Export results to CSV file

Step 3: Check Results

Option A: Notification (if enabled)

  • A persistent notification will appear in the top-right
  • Shows test results and troubleshooting advice
  • Click to expand full details

Option B: Logs

  • Go to SettingsSystemLogs
  • Search for growatt_modbus
  • View detailed test results

📊 Example Results

✅ Auto-Detection Success (VPP 2.01 Inverter)

🔌 Universal Register Scanner

✅ Auto-Detection: MIN 7000-10000TL-X (V2.01)
Confidence: HIGH
DTC Code: 5201 (register 30000)
Protocol Version: 2.01 (register 30099)

Scanned Registers:
• Range 0-124: 89 readable
• Range 3000-3249: 124 readable
• Range 30000-30999: 43 readable (V2.01)
• Range 31000-31999: 67 readable (V2.01)

Sample Values:
• Status (3000): Normal
• PV1 Voltage (3003): 284.50 V
• PV2 Voltage (3007): 289.00 V
• PV3 Voltage (3011): 291.20 V
• AC Voltage (3026): 240.10 V

CSV exported to: /config/growatt_register_scan_20250121_143022.csv

✅ Next Steps:
Your inverter supports VPP 2.01 and was auto-detected!
Configure the integration - auto-detection will identify it automatically.

⚠️ Legacy Inverter (No Auto-Detection)

🔌 Universal Register Scanner

⚠️ Auto-Detection: FAILED
Reason: DTC register (30000) not readable
Conclusion: Legacy protocol inverter (V1.39 or V3.05)

Scanned Registers:
• Range 0-124: 78 readable
• Range 3000-3249: 0 readable
• Range 30000-30999: 0 readable (V2.01 not supported)
• Range 31000-31999: 0 readable (V2.01 not supported)

Sample Values:
• Status (0): Normal
• PV1 Voltage (3): 285.30 V
• PV2 Voltage (7): 289.50 V
• AC Voltage (38): 241.20 V

CSV exported to: /config/growatt_register_scan_20250121_150033.csv

⚠️ Next Steps:
Your inverter uses legacy protocol (no V2.01 support).
When configuring the integration, you will need to manually select your inverter series.
Based on scan results, possible models: MIC or MIN 3-6kW

❌ All Tests Failed

🔌 Growatt Diagnostic: MIN 7000-10000TL-X

❌ All tests failed (0/6)

Results:
• ✅ Connected to 192.168.1.147:502
• ❌ Register 3000 (Status): Read error
• ❌ Register 3003 (PV1 Voltage): Read error
• ❌ Register 3007 (PV2 Voltage): Read error
• ❌ Register 3011 (PV3 Voltage): Read error
• ❌ Register 3026 (AC Voltage): Read error

❌ Troubleshooting:
No registers responded. Check:
• Wiring (try swapping A/B)
• Slave ID (try 1, 2, or 3)
• Inverter is powered on
• Baud rate is 9600

📊 Understanding Status Values

The Status register (shown as "Status: Normal" in results) indicates the inverter's current operating state:

Status Meaning When You'll See It
Waiting Waiting for sufficient PV power or grid Startup, low sun, early morning/late evening
Normal Operating normally Active power generation during day
Fault Fault condition detected Error state - check fault code for details

Typical Daily Cycle: - Sunrise: Waiting → Normal (as PV voltage builds) - Daytime: Normal (active generation) - Sunset: Normal → Waiting → Offline - Night: Inverter powered off (no response)

💡 Tip: If the scanner shows "Waiting" during sunny conditions, check for low PV voltage, grid issues, or inverter configuration.


🎯 What Gets Tested

MIN 3000-6000TL-X

  • Status register
  • PV1 & PV2 voltage
  • AC voltage
  • AC frequency

MIN 7000-10000TL-X

  • Status register
  • PV1, PV2, PV3 voltage
  • AC voltage

SPH 3000-10000 (Hybrid)

  • Status register (base range)
  • PV1 & PV2 voltage
  • AC voltage
  • Battery voltage
  • Battery SOC

MID 15000-25000TL3-X (Three-phase)

  • Status register
  • PV1 voltage
  • Grid voltages (R, S phases)
  • Grid frequency

MOD 6000-15000TL3-XH (Three-phase hybrid)

  • Status register
  • PV1 voltage
  • AC voltage (R phase)
  • Battery voltage
  • Battery SOC

🐛 Troubleshooting

"Service not found"

  • Integration files not installed correctly
  • Restart Home Assistant after installing files
  • Check /config/custom_components/growatt_modbus/ exists

"Connection refused"

  • Adapter not listening on port 502
  • Check adapter web interface settings
  • Verify TCP Server or Modbus Gateway mode

"Timeout" errors

  • Inverter is offline (try during daytime)
  • Wrong IP address
  • Network connectivity issue

All registers fail but connection succeeds

  • Wrong slave ID (try 1, 2, 3)
  • RS485 wiring incorrect (swap A/B)
  • Wrong inverter model selected
  • Baud rate mismatch (should be 9600)

Some registers work, others don't

  • Normal if inverter is offline (night time)
  • Some values may be 0V during standby
  • Battery registers won't work on non-hybrid models
  • Try again during daytime with sun

🔄 Testing Different Settings

You can run the diagnostic multiple times with different settings:

Test different slave IDs:

host: 192.168.1.100
slave_id: 1    # Try 1, then 2, then 3

Test different models:

inverter_series: min_7000_10000_tl_x    # Try different profiles

Test without notification:

notify: false    # Results only in logs

✅ Next Steps After Success

Once your diagnostic passes:

  1. Configure the integration:
  2. Go to SettingsDevices & Services
  3. Click Add Integration
  4. Search for Growatt Modbus
  5. Select your inverter model
  6. Enter the same connection details
  7. Check your sensors:
  8. Verify all expected sensors appear
  9. Compare values with inverter display
  10. Add to Energy Dashboard if desired
  11. Configure options:
  12. Set scan interval (default 30s)
  13. Enable grid power inversion if needed
  14. Adjust connection timeout if necessary

📝 Reporting Issues

If diagnostic fails, include this info when reporting:

  1. Full notification text or log output
  2. Inverter model (exact model number)
  3. Adapter type (EW11, USR-W630, etc.)
  4. Time of day you tested
  5. Inverter display shows (voltage, status, etc.)

Post in GitHub Issues with this information!


🎨 Advanced: Automation Example

You can even automate diagnostics! Run tests automatically:

automation:
  - alias: "Test Inverter Connection at Sunrise"
    trigger:
      - platform: sun
        event: sunrise
        offset: "+00:30:00"  # 30 min after sunrise
    action:
      - service: growatt_modbus.run_diagnostic
        data:
          host: "192.168.1.100"
          port: 502
          slave_id: 1
          inverter_series: "min_7000_10000_tl_x"
          notify: true

💡 Tips

  • Test during daytime - Inverter needs to be powered on
  • Wait 30 seconds after wiring changes before testing
  • Try all slave IDs - Some inverters use 2 or 3 instead of 1
  • Check adapter LEDs - Activity lights should blink during test
  • Compare with display - Values should match inverter screen
  • Test twice - First test might fail as inverter wakes up